More Evidence that Inspiratory Threshold Device Improves CPR

More evidence that inspiratory threshold device improves CPR (but only when CPR is done right!): 

Resuscitation online

Abstract


Objectives

To determine if the quality of CPR had a significant interaction with the primary study intervention in the NIH PRIMED trial.

Design

The public access database from the NIH PRIMED trial was accessed to determine if there was an interaction between quality of CPR performance, intervention, and outcome (survival to hospital discharge with modified Rankin Score (mRS) ≤3).

Setting

Multi-centered prehospital care systems across North America.

Patients

Of 8719 adult patients enrolled, CPR quality was electronically recorded for compression rate, depth, and fraction in 6199 (71.1%), 3750 (43.0%) and 6204 (71.2%) subjects, respectively. “Acceptable” quality CPR was defined prospectively as simultaneous provision of a compression rate of 100/min (±20%), depth of 5 cm (±20%) and fraction of >50%. Significant interaction was considered as p < 0.05.

Intervention

Standard CPR with an activated versus sham (inactivated) ITD.

Measurements and main results

Overall, 848 and 827 patients, respectively, in the active and sham-ITD groups had “acceptable” CPR quality performed (n = 1675). There was a significant interaction between the active and sham-ITD and compression rate, depth and fraction as well as their combinations. The strongest interaction was seen with all three parameters combined (unadjusted and adjusted interaction p-value, <0 .001="" 34="" acceptable="" active-itd="" all="" an="" compared="" cpr="" discharge="" for="" hospital="" i="" increased="" mrs="" of="" performed="" presenting="" quality="" respectively="" rhythms="" sham="" survival="" to="" use="" versus="" was="" when="" with="">p

= 0.006). The opposite was true for patients that did not receive “acceptable” quality of CPR. In those patients, use of an active – ITD led to significantly worse survival to hospital discharge with mRS ≤3 compared to sham (34/1012 [3.4%] versus 62/1061 [5.8%], p = 0.007).

Conclusions

There was a statistically significant interaction between the quality of CPR provided, intervention, and survival to hospital discharge with mRS ≤3 in the NIH PRIMED trial. Quality of CPR delivered can be an underestimated effect modifier in CPR clinical trials.

Previous Article